China's Pdu's system of custom manufacturing manufacturers with the rapid development of its communication industry has been hundreds of more, and each manufacturer claims to be able to customize on demand. We are here to explain the difference and relationship between PDU customization and PDU manufacturing.
Pdu customization is due to the rapid development of the IDC server room, in order to meet the equipment changes in the server room and service, the service mainly emphasizes the following points
1: Matching the form and quantity between the power plug of the equipment in the server room and the output socket of the PDU;
2: PDU's way of taking power and power and the power supply system of the room wiring output way and power matching
3: PDU control and protection devices and front-end machine room power supply line control and protection device level and the way of matching, column head distribution cabinet if the SPD surge lightning protection device is used level two, as the next level of PDU SPD surge lightning protection should be three; if the column head distribution cabinet tap open is 32A, PDU bearing can not be lower than 32A and so on.
4: PDU's installation method and cabinet, rack foot gauge, and mounting hole positioning and size matching.
5: PDU's electrical measurement and control and computer room monitoring, ring control system communication mode, communication protocol matching;
6: Matching of program provision and safety standards
Pdu manufacturing is to determine the premise of customer demand, the use of advanced production equipment and testing equipment, in accordance with the customer's clear needs to produce and assemble into the customer's desired products. PDU production manufacturer depends on the following points:
A. The sophistication of the equipment and the proficiency of the operating employees
B.The sophistication of the production process and the completeness of the production flow
C. The accuracy of the mold and the quantity and accuracy of the material grade selection
D. Factory certification level and product certification integrity
E. The ability to control the cost and the ability to stock raw and auxiliary materials and the ability to minimize the order time and delivery time.
F. The ability to digest and understand the customer's needs and the ability to meet the technology.
The current state of the industry is Pdu manufacturers and PDU producers confused, many PDU manufacturers also come to act as Pdu producers, due to the distance from the customer, can not implement the customer's accurate needs, to provide solutions are only limited to their own manufacturing capacity, can not maximize to meet the actual needs of the computer room power distribution; there are also a number of agents and dealers and even hardware shops and computer city supplies Some agents and distributors or even hardware stores and computer city supplies to act as Pdu custom business role, the equipment in the room and the power distribution of common sense can not figure out the PDU manufacturer's ability to figure out, can only simply be a "megaphone".
A Pdu customizer should have a good knowledge of Pdu safety regulations and related standards, many years of experience in power distribution in server rooms, and the ability to complete the program, there is a convenient and fast "PDU customization system" tool to provide to the server room owners and server room contractors and maintenance of the server room in the server room site one by one to match the wide range of Pdu manufacturer resources, and the ability to provide a convenient and fast "PDU customization system" tool to provide to the server room owners and server room contractors and maintenance of the server room site one by one to match the extensive Pdu production manufacturer resources. We have the ability to provide program guidance and program modification to the demand side of power distribution in server rooms, and the ability to provide technical support to Pdu manufacturers.